ZWave
MDD, Zimmer Aesthetic
ZWave
The high energy radial shockwaves scientifically proved to have a large impact on collagen structure and the skin connective tissue, improving blood circulation.
It stimulates collagen formation, while the skin becomes more elastic and its firmness is visible after only a few treatments.
Thanks to the ZWave radial shockwave unit, it is also possible to significantly improve skin firmness, skin elasticity and collagen regeneration. Fat reduction, for example, after CryolipolysisTM or injection lipolysis is also enhanced by using the ZWave.
Skin tightening and body contouring are becoming increasingly important in the modern practice. After several treatments for fat reduction, such as e.g. CryolipolysisTM, liposuction, or injection lipolysis, a more extensive application for skin tightening is urgently recommended and expected by the patient. Various studies and user observations have proven its effectiveness.
Patient-friendly application
Using radial shockwaves for skin tightening, cellulite and general connective tissue tightening treatments has the following advantages:
non-invasive treatment
no down time
pain-free application
simple application
visible results
versatile
Preset treatment recommendations:
- Cellulite
- Stretch marks
- Combination with CryolipolysisTM
- Combination with radio frequency
- Combination with ultrasound
- Combination with laser (Softlaser)
- Skin tightening (general)
- Aesthetic scar treatment
- Supporting lymphatic drainage
The high energy radial shockwaves consists of two different parts – positive pressure pulse and a comparatively small tensile wave component. The shockwave squeezes the surrounding tissue and breaks the grid structure of the molecules. The tensile wave leads to a collapse of the gas bubbles within the fat structures (cavitation), which re-expand after the high energy radial shockwaves and thus ensure a destabilization of the fat structures. Thanks to its 39 mm applicator head, the ZWave transmits the radial shockwaves directly and with a high precision into the tissue. It was observed and documented that the introduction of a mechanical pressure wave triggers various tissue reactions that have a beneficial effect on the skin structure.
Technical Data
Technology Compressor-free balistic shockwave system with electromagnetic generator
as projectile accelerator, 1-22Hz, 60-185 mJ
Programs 10 presets application fields plus respective detailed treatment recommendations
Control Unit 12” colour touch screen for all software operation
Controller for energy frequency. Handpiece operation via multi directional foot switch
Memory & Update SD card for application menu memory
Favorites and adaptive programmes (240 places) / error log / firmware update
Main Voltages 100 – 240 V / 50/60 Hz ; 220V / 60 Hz
Protection Class I
Dimension, weight W 322 mm / D 235 mm / H 130 mm, 2.7kg without handpiece
Guarantee 2.000.000 shocks on each shockwave generator and two years for the unit
Reviews
There are no reviews yet.